jambrass

Bronze transformer clamps

Bronze transformer clamps

$11.64 / kg

kg

Comprehensive Technical Overview of Bronze Transformer Clamps

We are one of the leading manufacturers and exporters of Bronze Transformer ClampsTransformer Connection Clamps, and Electrical Transformer Fittings from India. We have been supplying high-quality Bronze Busbar ClampsTransformer Terminal ClampsHV/LV Connection ClampsTransformer Grounding ClampsCustom Transformer Clamps, and Special Application Transformer Fittings to the world market for many decades. Our state-of-the-art manufacturing facility specializes in producing premium Bronze Transformer Connection Systems using advanced copper alloy formulationprecision sand castinghot forging technologyCNC machiningheat treatment processessurface finishingautomated assemblyelectrical testing, and comprehensive quality assurance systems. With over three decades of global experience in Bronze Transformer Clamp manufacturing, we serve diverse industries including power transmission and distributionelectrical utilitiesrenewable energyindustrial power systemsrailway electrificationsubstation equipmenttransformer manufacturing, and electrical infrastructure projects. Our expertise encompasses working with various bronze alloys including Gunmetal Bronze (BS 1400 LG2)Phosphor Bronze (BS 1400 PB4)Aluminum Bronze (BS 1400 AB2), and High-Strength Bronze Alloys. We manufacture Bronze Transformer Clamps in current ratings from 200A to 5000A, voltage ratings up to 36kV, conductor sizes from 25mm² to 1000mm², maintaining temperature ratings from -40°C to 150°C, excellent electrical conductivity (minimum 18% IACS), compliance with IEC 60076, IS 2026, ANSI C119.4, ASTM B283 standards, and reliable performance in demanding electrical power applications.

Types of Bronze Transformer Clamps

HV Transformer Bushings Clamps
High Voltage Bushing Connectors specifically designed for transformer HV bushings, featuring precision-machined contact surfaces and superior dielectric properties. Available for bushings from 11kV to 33kV with current ratings from 400A to 2000A. These High Voltage Connection Clamps provide reliable connections for power transformer bushingsHV cable terminationssubstation connections, and transformer incomer systems where high dielectric strength is critical.

LV Transformer Terminal Clamps
Low Voltage Terminal Connectors for transformer LV side connections, featuring heavy-duty construction and optimized current distribution. Current ratings from 600A to 5000A with multiple conductor configurations. These High Current Clamps are essential for transformer LV terminalsbusbar connectionscable terminations, and distribution systems where high current carrying capacity is required.

Grounding Transformer Clamps
Transformer Grounding Connectors for neutral and body grounding applications, featuring enhanced conductivity and corrosion resistance. Available in various configurations including strap clamps and rod connectors. These Grounding System Clamps are crucial for transformer neutral groundingtank groundingcore grounding, and safety grounding systems where reliable earth continuity is mandatory.

Tap Changer Connection Clamps
Tap Changer Terminal Connectors with precision design for tap changer connections, featuring fine adjustment capability and secure contact. These Adjustable Connection Clamps are designed for transformer tap changersvoltage regulation systemsOLTC connections, and tap selector switches where precise and reliable connections are critical.

Radiator and Coolant Pipe Clamps
Cooling System Clamps for transformer radiator and pipe connections, featuring thermal stability and mechanical strength. These Thermal Resistant Clamps provide secure connections for transformer radiatorscoolant pipesbushing connections, and cooling system components where thermal cycling resistance is important.

Material Specifications & Properties

Bronze Alloy Composition & Electrical Properties

Alloy Type Composition Conductivity (% IACS) Tensile Strength (MPa) Yield Strength (MPa) Maximum Service Temperature
Gunmetal Bronze LG2 85% Cu, 5% Zn, 5% Sn, 5% Pb 25% 240-300 120-150 150°C
Phosphor Bronze PB4 90% Cu, 10% Sn, 0.2% P 18% 350-450 200-250 180°C
Aluminum Bronze AB2 85% Cu, 10% Al, 3% Fe, 2% Ni 20% 600-750 300-400 200°C
High-Strength Bronze 88% Cu, 8% Sn, 2% Zn, 2% Pb 22% 400-500 180-220 160°C

Performance Specifications & Ratings

Parameter LV Clamp Range HV Clamp Range Test Standard
Current Rating 600A – 5000A 400A – 2000A IEC 60076
Voltage Rating Up to 1.1kV 11kV – 33kV IEC 60137
Short Circuit Withstand 25kA – 100kA 16kA – 50kA IEC 61439
Contact Resistance <15μΩ <20μΩ IEC 61238
Mechanical Strength 20kN – 100kN 15kN – 60kN IS 2026

Manufacturing Excellence

Advanced Manufacturing Process
Sand Casting Technology: Precision sand casting for complex geometries and superior surface finish
Hot Forging Process: 800-ton forging presses for high-strength components
CNC Precision Machining: 5-axis CNC machining centers maintaining tolerances of ±0.02mm
Heat Treatment: Solution treatment and precipitation hardening for optimal properties
Surface Treatment: Tin plating, silver plating, or passivation treatments
Quality Testing: 100% dimensional, visual, and electrical inspection

Quality Assurance Protocols
Material Certification: Mill certificates with full chemical composition analysis
Dimensional Control: CMM inspection with statistical process control
Mechanical Testing: Tensile testing, compression testing, and fatigue testing
Electrical Testing: Contact resistance measurement and dielectric testing
Performance Validation: Thermal cycling, salt spray testing, and accelerated aging

Technical Specifications & Performance Data

Current Carrying Capacity & Mechanical Specifications

Clamp Type Transformer Rating Current Rating Conductor Size Bolt Size Torque Value Weight
BTC-LV-630 630kVA 630A 185-300mm² M16 80-100Nm 1.2kg
BTC-LV-1000 1000kVA 1000A 300-500mm² M20 120-150Nm 2.0kg
BTC-LV-1600 1600kVA 1600A 400-630mm² M24 150-180Nm 3.2kg
BTC-LV-2500 2500kVA 2500A 630-800mm² M27 180-220Nm 4.8kg
BTC-HV-11 11kV 400A 150-240mm² M12 60-70Nm 0.8kg
BTC-HV-22 22kV 630A 185-300mm² M16 80-100Nm 1.4kg
BTC-HV-33 33kV 800A 240-400mm² M20 120-150Nm 2.2kg

Electrical Performance Specifications

Performance Parameter LV Clamp Value HV Clamp Value Test Condition
Contact Resistance <15μΩ <20μΩ At 100A DC
Temperature Rise 65°C at rated current 55°C at rated current Ambient 40°C
Short Circuit Withstand 50kA for 1s 25kA for 1s IEC 61439
Partial Discharge <5pC <3pC 1.1 x rated voltage
Dielectric Strength 3kV for 1min 70kV for 1min IEC 60137

Transformer Compatibility & Applications

Distribution Transformers (11kV/433V)
Pole Mounted Transformers: HV and LV bushing connections for 25kVA to 250kVA transformers
Pad Mounted Transformers: Complete clamping solutions for 315kVA to 1000kVA units
Compact Substations: Integrated clamping systems for pre-fabricated substations

Power Transformers (33kV and above)
Substation Transformers: Heavy-duty clamps for 5MVA to 50MVA power transformers
Generator Transformers: Special clamps for large generator transformer applications
Auto Transformers: Custom clamps for auto transformer applications

Special Application Transformers
Rectifier Transformers: Clamps for high-harmonic applications
Furnace Transformers: High-temperature clamps for furnace applications
Traction Transformers: Vibration-resistant clamps for railway applications

International Standards & Certifications

Global Compliance & Approvals
IEC 60076: Power transformers
IS 2026: Indian standard for power transformers
ANSI C119.4: Electric connectors
ASTM B283: Copper-alloy die forgings
IEC 60137: Insulated bushings

Testing & Certification Standards
Temperature Rise Test: IEC 60076 for current carrying capacity
Short Circuit Test: IEC 61439 for dynamic stability
Dielectric Test: IEC 60137 for insulation coordination
Mechanical Test: IS 2026 for mechanical strength

Installation Guidelines & Maintenance

Professional Installation Procedure

  1. Surface Preparation: Clean transformer bushings and clamp surfaces thoroughly

  2. Clamp Selection: Verify clamp rating matches transformer specifications

  3. Alignment Check: Ensure proper alignment with transformer terminals

  4. Torque Application: Use calibrated torque wrench with specified values

  5. Contact Verification: Check for proper contact and pressure distribution

  6. Final Inspection: Verify complete installation and electrical continuity

Maintenance Best Practices
Regular Inspection: Annual thermal imaging and visual inspection
Preventive Maintenance: Triennial torque verification and contact cleaning
Performance Monitoring: Continuous temperature monitoring in critical applications
Replacement Schedule: 30-year recommended service life with proper maintenance

Frequently Asked Questions

Q1: Why use bronze clamps for transformer connections instead of aluminum?
Bronze offers superior mechanical strength, better corrosion resistance, higher temperature capability, excellent arc resistance, and proven long-term reliability in transformer applications, making it ideal for critical power connections.

Q2: Are these clamps compatible with all transformer manufacturers?
Yes, our bronze transformer clamps are designed to be compatible with major transformer manufacturers including ABB, Siemens, Schneider, Toshiba, and other international brands. We also provide custom solutions for specific requirements.

Q3: What is the maximum short-circuit current your clamps can withstand?
Our LV clamps can withstand up to 100kA for 1 second, while HV clamps are rated for up to 50kA for 1 second, complying with international standards for transformer applications.

Q4: Do you provide complete transformer connection kits?
Yes, we provide complete transformer connection kits including all necessary clamps, hardware, and installation accessories. These kits are customized for specific transformer ratings and configurations.

Q5: What is the expected service life of your bronze transformer clamps?
Our bronze transformer clamps have a minimum service life expectancy of 30+ years when properly installed and maintained, with proven performance in utility applications worldwide.

Q6: What testing do you perform on finished transformer clamps?
We perform 100% dimensional inspection, mechanical strength testing, contact resistance measurement, and sample destructive testing. Additionally, we conduct type tests including temperature rise, short circuit, partial discharge, and dielectric testing.

Contact Us Today – Request Quote for Bronze Transformer Clamps

Ready to discuss your Bronze Transformer Clamp requirements for power distribution, transformer manufacturing, substation projects, or custom electrical connection solutions?

Request a Quote: Send your specifications including transformer rating, voltage class, current rating, quantity, and application details to sales@jambrass.com for a detailed quotation within 24 hours.

Technical Support: Email your application requirements or technical drawings for clamp selection guidance, material recommendation, and certification assistance.

Call Us: +91-22-43449300 / +91-22-43449323 (Monday-Friday, 9:00 AM – 6:00 PM IST)

Office Address: 1406, 14th Floor, Dalamal Tower, Nariman Point, Mumbai – 400021, Maharashtra, INDIA

Factory Address: Plot 10B, GIDC Industrial Estate, Shanker Tekari, Udyognagar, Jamnagar, Gujarat, India – 361004

Contact Person: Mr. Mehul Vora

Email: sales@jambrass.com

Shopping Cart
Scroll to Top